Product Specifications
Download printer-friendly document (PDF)
The Shear Guard® coupling support protects flexible couplings joined to clay pipe from shear failure and pipe offsets.
|
- Available for 4", 6", 8", 10" and 12" diameter pipe for clay pipe and cast iron pipe
|
- Simple to install – Slides over conventional flexible coupling
|
- Installation is hassle free with no additional hardware or adhesives required
|
- Reduced installation time
|
|
|
SDR 35/26 pipe |
|
ABS pipe |
|
PVC SCH 40 pipe |
|
cast iron and clay |
- Helps avoid expensive warranty repairs
|
- Reduced cost when compared to other methods such as concrete encasement
|
|
|
|
Mechanical Testing Results:
Tensile Tests - 2" Gage Length, 0.2% Offset
SQR Dimensions Inches |
Load,
Lbs |
Max Stress,
PSI |
Elongation
% |
ID |
Width |
Thickness |
Area, In2 |
A1 |
0.502 |
0.193 |
0.0969 |
576 |
5,940 |
6.5 |
A2 |
0.502 |
0.193 |
0.0969 |
575 |
5,930 |
8.3 |
B1 |
0.4955 |
0.190 |
0.0941 |
694 |
7,377 |
3.3 |
B2 |
0.492 |
0.190 |
0.0935 |
782 |
8,358 |
15.3 |
Hardness Results -
Sample ID |
Individual Hardness Values,
D Shore |
Average,
D Shore |
A1 |
75 |
77 |
77 |
76 |
78 |
75 |
76 |
A2 |
79 |
78 |
76 |
77 |
77 |
77 |
77 |
B1 |
81 |
81 |
80 |
81 |
81 |
83 |
81 |
B2 |
82 |
83 |
82 |
82 |
82 |
82 |
82 |
Impact Testing -
|
Dimensions, Inch |
Impact Energy |
|
ID |
Width under
Notch |
Depth under
Notch |
Ft. - Lb. |
Mode of Failure |
A2 |
0.2355 |
0.399 |
2.96 |
C |
B1 |
0.236 |
0.395 |
2.84 |
C |
*Performed by an independent lab |